To quantify the fluorescent microsphere (FM) content in cardiac tissue, which is an indicative of blood flow, fluorescence imaging of both sides of the pig heart slice was employed. Despite the light scattering inside the tissue and contributions from multiple tissue layers to the total emission, it is shown that the fluorescence intensity at any pixel is proportional to the FM content and the fluorescence image may be transformed to the image of the FM concentration. A convenient standard for the emission-FM concentration transformation is proposed. The approach has several advantages in comparison with the traditional digestion & extraction method such as: non-destructiveness, high spatial resolution, high throughput, repeatability and simplicity of operation.