期刊
JOURNAL OF BIOMECHANICS
卷 78, 期 -, 页码 161-165出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2018.07.032
关键词
Cell-matrix interaction; Fibroblast; Force monitor; Mechanics; Tissue engineering
资金
- Lundbeck foundation
- Council for Independent Research in Medical Sciences (FSS)
- NOVO Nordisk Foundation
- Nordea Foundation (Center for Healthy Aging)
- Wellcome Trust [110126/Z/15/Z, 203128/Z/16/Z]
Tendons transmit contractile muscular force to bone to produce movement, and it is believed cells can generate endogenous forces on the extracellular matrix to maintain tissue homeostasis. However, little is known about the direct mechanical measurement of cell-matrix interaction in cell-generated human tendon constructs. In this study we examined if cell-generated force could be detected and quantified in engineered human tendon constructs, and if glycosaminoglycans (GAGs) contribute to tendon force transmission. Following de-tensioning of the tendon constructs it was possible to quantify an endogenous re-tensioning. Further, it was demonstrated that the endogenous re-tensioning response was markedly blunted after interference with the cytoskeleton (inhibiting non-muscle myosin-dependent cell contraction by blebbistatin), which confirmed that re-tensioning was cell generated. When the constructs were elongated and held at a constant length a stress relaxation response was quantified, and removing 27% of the GAG content of tendon did not alter the relaxation behavior, which indicates that GAGs do not play a meaningful role in force transmission within this system. (C) 2018 The Author(s). Published by Elsevier Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐