The use of surface strain data and a neural networks solution method to determine lumbar facet joint loads during in vitro spine testing

期刊

JOURNAL OF BIOMECHANICS
卷 41, 期 12, 页码 2647-2653

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2008.06.010

关键词

facet load; surface strain; computational model; neural network; lumbar spine

向作者/读者索取更多资源

A new method for determining facet loads during in vitro spine loading using strain gauges and a neural networks solution method was investigated. A test showed that the new solution method was more robust than and as accurate as a previously presented graphical solution method for computing facet loads using surface strain. The technique was subsequently utilized to assess facet loads at L1-L2 during flexibility testing [7.5 N m pure moments in flexion (FL), extension (EX), right and left axial rotation (AR), and right and left lateral bending (LB)], and stiffness testing (FL-EX with 400 N compressive follower load) of six human lumbar spine segments (T12-L2). In contrast to other techniques, such as thin film sensors or pressure-sensitive film, the strain-gauge method leaves the facet joint capsule intact during data collection, presumably allowing more natural load transmission. During flexibility tests, the mean ( standard deviation) calculated facet loads (in N) were 46.1 +/- 41.3 (FL), 51.5 +/- 39.0 (EX), 70.3 +/- 43.2 (AR-contralateral side), 31.3 +/- 33.4 (AR-ipsilateral side), 30.6 +/- 29.1 (LB-contralateral side), and 32.0 +/- 44.4 (LB-ipsilateral side). During stiffness tests, the calculated facet loads were 45.5 +/- 40.4 (upright), 46.6 +/- 41.9 (full FL), and 75.4 +/- 39.0 (full EX), corresponding to an equivalent of 11.4%, 11.6%, and 18.8% of the compressive follower load (upright, full FL and EX, respectively). The error associated with this technique, which was below 11 N for loads up to 125 N, is comparable to that reported with other techniques. The new method shows promise for assessing facet load during in vitro spine testing, an important parameter when evaluating new implant systems and surgical techniques. (c) 2008 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据