4.3 Article

Clinical Assessment of Scapular Positioning in Musicians: An Intertester Reliability Study

期刊

JOURNAL OF ATHLETIC TRAINING
卷 44, 期 5, 页码 519-526

出版社

NATL ATHLETIC TRAINERS ASSOC INC
DOI: 10.4085/1062-6050-44.5.519

关键词

scapular winging; observation; shoulder

资金

  1. Department of Health Sciences, University College Antwerp, Antwerp, Belgium [G826, G801]

向作者/读者索取更多资源

Context: The reliability of the measurement of the distance between the posterior border of the acromion and the wall and the reliability of the modified lateral scapular slide test have not been studied. Overall, the reliability of the clinical tools used to assess scapular positioning has not been studied in musicians. Objective: To examine the intertester reliability of scapular observation and 2 clinical tests for the assessment of scapular positioning in musicians. Design: Intertester reliability study. Setting: University research laboratory. Patients or Other Participants: Thirty healthy student musicians at a single university. Main Outcome Measure(s): Two assessors performed a standardized observation protocol, the measurement of the distance between the posterior border of the acromion and the wall, and the modified lateral scapular slide test. Each assessor was blinded to the other's findings. Results: The intertester reliability coefficients (K) for the observation in relaxed position, during unloaded movement, and during loaded movement were 0.41, 0.63, and 0.36, respectively. The K values for the observation of tilting and winging at rest were 0.48 and 0.42, respectively; during unloaded movement, the K values were 0.52 and 0.78, respectively; and with a 1-kg load, the K values were 0.24 and 0.50, respectively. The intraclass correlation coefficient (ICC) of the measurement of the acromial distance was 0.72 in relaxed position and 0.75 with the participant actively retracting both shoulders. The ICCs for the modified lateral scapular slide test varied between 0.63 and 0.58. Conclusions: Our results demonstrated that the modified lateral scapular slide test was not a reliable tool to assess scapular positioning in these participants. Our data indicated that scapular observation in the relaxed position and during unloaded abduction in the frontal plane was a reliable assessment tool. The reliability of the measurement of the distance between the posterior border of the acromion and the wall in healthy musicians was moderate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据