4.6 Article

Joint Registries as Continuous Surveillance Systems: The Experience of the Catalan Arthroplasty Register (RACat)

期刊

JOURNAL OF ARTHROPLASTY
卷 29, 期 3, 页码 484-490

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2013.07.048

关键词

hip arthroplasty; knee arthroplasty; registries; outcomes assessment

向作者/读者索取更多资源

The aim was to present results on prosthesis performance in Catalonia for the period 2005-2010. All publicly funded hospitals submit in an electronic format data on hip and knee arthroplasties: patients' insurance identification number, hospital, joint (hip/knee), type of arthroplasty (primary/revision), side (right/left), date of surgery and prosthesis (manufacturer name and catalogue number). A standard survival analysis based on Kaplan-Meier estimation was carried out. Fifty-two hospitals have sent information to the RACat which has data on 36,951 knee and 26,477 hip arthroplasties. Cumulative prostheses revision risks at 3 years were 3.3% (95% CI: 3.1-3.6) for knee, 2.9% (95% CI: 2.5-3.3) for total hip and 2.5% (95% CI: 2.0-3.1) for partial hip. When compared to other registries a higher risk of revision was observed. (C) 2014 Elsevier Inc. All rights reserved.