4.6 Article

Cementless Bipolar Hemiarthroplasty Using a Hydroxyapatite-Coated Long Stem for Osteoporotic Unstable Intertrochanteric Fractures

期刊

JOURNAL OF ARTHROPLASTY
卷 26, 期 4, 页码 626-632

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2010.05.010

关键词

hip; intertrochanteric fracture; osteoporosis; bipolar hemiarthroplasty; cementless stem; hydroxyapatite coating

向作者/读者索取更多资源

Treating senile osteoporotic patients with unstable hip fractures remains a challenge. We evaluated the results of 87 cementless bipolar hemiarthroplasties using an extensively hydroxyapatite-coated long stem for unstable intertrochanteric fractures in senile patients. Sixty-one hips were followed for a minimum of 2 years (mean, 36 months) postoperatively. The mean Merle d'Aubigne and Poste] hip score was 14.7 points (12-18). Two hips were reoperated because of infection. Of the remaining 59 hips, 48 were included in the radiographic analysis. Although cortical porosis around the stem was seen in 18 hips, there was no loosening or osteolysis. Cement less bipolar hemiarthroplasty using an extensively hydroxyapatite-coated long stem is a useful option for the treatment of unstable intertrochanteric fracture in senile patients with severe osteoporosis.