4.6 Article

The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty

期刊

JOURNAL OF ARTHROPLASTY
卷 25, 期 4, 页码 529-532

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2009.04.011

关键词

digital templating; total hip arthroplasty; reliability; radiography

向作者/读者索取更多资源

We analyzed the reproducibility and reliability of computer templating in primary uncemented total hip arthroplasties as compared to standard onlay templating techniques with hardcopy radiographs from a digital source. Digital templating showed good intraobserver and interoberserver reliability with intraclass correlation coefficient values greater than 0.7. Using computer templating, prediction of sizing to within 1 size was 85% accurate for femoral stem sizing and 80% accurate for acetabular sizing. Using onlay templating, prediction of sizing to within 1 size was 85% accurate for femoral sizing and 60% accurate for acetabular sizing. We conclude that the introduction of digital templating has significant benefits in preoperative planning for total hip arthroplasty over onlay templating.