4.5 Article

Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not required in patients at rest

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 105, 期 6, 页码 1858-1863

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.91052.2008

关键词

brachial pressure; augmentation index; travel time

向作者/读者索取更多资源

Westerhof BE, Guelen I, Stok WJ, Lasance HA, Ascoop CA, Wesseling KH, Westerhof N, Bos WJ, Stergiopulos N, Spaan JA. Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not required in patients at rest. J Appl Physiol 105: 1858-1863, 2008. First published October 9, 2008; doi:10.1152/japplphysiol.91052.2008.-Central aortic pressure gives better insight into ventriculo-arterial coupling and better prognosis of cardiovascular complications than peripheral pressures. Therefore transfer functions (TF), reconstructing aortic pressure from peripheral pressures, are of great interest. Generalized TFs (GTF) give useful results, especially in larger study populations, but detailed information on aortic pressure might be improved by individualization of the TF. We found earlier that the time delay, representing the travel time of the pressure wave between measurement site and aorta is the main determinant of the TF. Therefore, we hypothesized that the TF might be individualized (ITF) using this time delay. In a group of 50 patients at rest, aged 28-66 yr (43 men), undergoing diagnostic angiography, ascending aortic pressure was 119 +/- 20/70 +/- 9 mmHg (systolic/diastolic). Brachial pressure, almost simultaneously measured using catheter pullback, was 131 +/- 18/67 +/- 9 mmHg. We obtained brachial-to-aorta ITFs using time delays optimized for the individual and a GTF using averaged delay. With the use of ITFs, reconstructed aortic pressure was 121 +/- 19/69 +/- 9 mmHg and the root mean square error (RMSE), as measure of difference in wave shape, was 4.1 +/- 2.0 mmHg. With the use of the GTF, reconstructed pressure was 122 +/- 19/69 +/- 9 mmHg and RMSE 4.4 +/- 2.0 mmHg. The augmentation index (AI) of the measured aortic pressure was 26 +/- 13%, and with ITF and GTF the AIs were 28 +/- 12% and 30 +/- 11%, respectively. Details of the wave shape were reproduced slightly better with ITF but not significantly, thus individualization of pressure transfer is not effective in resting patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据