In order to interpret field data from small-loop electromagnetic (EM) instruments with fixed source-receiver separation, 1D inversion method is commonly used due to its efficiency with regard to computation costs. This application of 1D inversion is based on the assumption that small-offset broadband EM signals are insensitive to lateral resistivity variation. However, this assumption can be false when isolated conductive bodies such as man-made objects are embedded in the earth. Thus, we need to clarify the applicability of the 1D inversion method for small-loop EM data. In order to systematically analyze this conventional inversion approach, we developed a 2D EM inversion algorithm and verified this algorithm with a synthetic EM data set. 1D and 2D inversions were applied to synthetic and field EM data sets. The comparison of these inversion results shows that the resistivity distribution of the subsurface constructed by the 1D inversion approach can be distorted when the earth contains man-made objects, because they induce drastic variation of the resistivity distribution. By analyzing the integrated sensitivity of the small-loop EM method, we found that this pitfall of 1D inversion may be caused by the considerable sensitivity of the small-loop EM responses to lateral resistivity variation. However, the application of our 2D inversion algorithm to synthetic and field EM data sets demonstrate that the pitfall of 1D inversion due to man-made objects can be successfully alleviated. Thus, 2D EM inversion is strongly recommended for detecting conductive isolated bodies, such as man-made objects, whereas this approach may not always be essential for interpreting the EM field data. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据