4.7 Article

Quantification of transient signals in multiple collector inductively coupled plasma mass spectrometry: accurate lead isotope ratio determination by laser ablation of individual fluid inclusions

期刊

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
卷 26, 期 3, 页码 475-492

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c0ja00140f

关键词

-

资金

  1. Swiss National Science Foundation [PP002-106569, 200020-107955]

向作者/读者索取更多资源

This work establishes the analytical protocol for accurate Pb isotopic analysis of fast transient signals by multiple-collector ICP-MS instruments. Individual synthetic fluid inclusions of known Pb and Tl isotopic compositions (dissolved SRM 981 with or without SRM 997 from NIST, enclosed in quartz by a hydrothermal crack annealing technique) were liberated by 193 nm UV laser ablation (LA). Data were recorded on Faraday detectors, for which correction schemes for bias in amplifier response (tau correction) are presented and evaluated. tau-Corrected Pb isotope data reveal LA-induced isotope fractionation amounting to similar to 0.5% amu(-1) for Pb isotopes over the course of an entire fluid inclusion ablation. Instrumental mass bias correction was effected within-run using Tl provided by the fluid inclusion itself or admixed to the ablation aerosol via desolvated nebulization. Isotope ratios derived from the transient signals were either based on individual readings or on bulk signal integration, of which the latter produces significantly more accurate data. The external precision achieved by ablating SRM 610 glass with a 60 mm beam is +/-0.011% (2 SD, relative) for (208)Pb/(206)Pb and (207)Pb/(206)Pb ratios and +/-0.032% for Pb isotope ratios normalized to mass 204 (n = 18). Inclusion-to-inclusion reproducibilities (n = 11; similar to 0.1 ng Pb per inclusion) are +/-0.05% (2 SD; (208)Pb/(206)Pb and (207)Pb/(206)Pb) and +/-0.13% ((20x)Pb/(204)Pb), respectively; inclusions containing as little as 0.005 ng Pb returned +/-0.1% and +/-0.8%. These results are accurate as demonstrated by analysis of synthetic fluid inclusions containing SRM 981 Pb. The analytical protocol presented here for measuring isotope ratios on minute analyte quantities by multiple-collector ICP-MS in fast transient signal mode has great potential for applications to geochemical, archaeological, environmental and possibly biochemical problems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据