This study evaluates the necessity of matrix matching for laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) lead isotope ratio measurements of lead-poor (<70 mu g g(-1) total Pb) feldspar and sulfide using standard-sample-standard bracketing to correct for mass discrimination. Lead isotope ratios of three different feldspar minerals and three different sulfide matrices were measured by LA-MC-ICPMS to determine the quality of data possible when calibrating samples with standards having different physical characteristics and chemical compositions. Lead isotope ratios for the feldspars were calibrated against NIST 612 and BCR2-G. The average Pb-206,Pb-207,Pb-208/Pb-204 and Pb-207,Pb-208/Pb-206 ratios determined by LA-MC-ICPMS on all three feldspars, independent of standard, are within 0.40% of the average TIMS measurements made in this study on the same grains. External precisions for the LA-MC-ICPMS measurements are better than 0.60% (RSD, 1 sigma). Lead isotope ratios for 3 sulfides were determined by LA-MC-ICPMS using either NIST 612 or PB-1, a synthetic sulfide glass, as the external calibration standard. For the two sulfides that contain little to no mercury the mean Pb-206,Pb-207,Pb-208/Pb-204 and Pb-207,Pb-208/Pb-206 ratios are accurate within 0.40% of the average TIMS measurements made in this study on the same grains, with only subtle differences in results between matrix-matched (PB-1) and non-matrix-matched (NIST 612) analyses. Lead isotope ratios determined for MASS-1, a pressed powder sulfide containing high levels of mercury (similar to 60 mg g(-1)), are highly variable. This is a result of intrinsic lead isotope heterogeneity in MASS-1 and errors in the isobaric overlap corrections for Hg-204 on Pb-204 caused by fractionation of Hg/Pb during spot analyses. Despite significant differences in the ablation behavior of silicate glass, feldspar and sulfide, the results demonstrate that precise and accurate lead isotope ratio data can be obtained by LA-MC-ICPMS for feldspar and sulfide containing little to no mercury, using commonly available silicate glasses as calibration standards.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据