4.6 Article

Numerical and experimental deposition of fine respiratory aerosols: Development of a two-phase drift flux model with near-wall velocity corrections

期刊

JOURNAL OF AEROSOL SCIENCE
卷 39, 期 1, 页码 48-70

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jaerosci.2007.10.001

关键词

submicrometer particle deposition; Eulerian mixture model; respiratory dosimetry; microdosimetry; respiratory drug delivery; deposition enhancement factor; respiratory particle dynamics

向作者/读者索取更多资源

Simulations of fine aerosols (100 nm <= d(p) <= 1 mu m) in the respiratory tract are challenging due to low particle deposition rates and the combined effects of diffusional and inertial deposition mechanisms. Further-more, validations of fine respiratory aerosol deposition are difficult due to a lack of localized experimental data. The objective of this study is to develop and test a continuous two-phase model for simulating the regional and local deposition of dilute fine aerosols in an idealized double bifurcation segment of the respiratory tract. To evaluate the developed transport model, novel in vitro deposition results for 400 nm particles have been determined in a double bifurcation geometry of respiratory generations G3-G5. In addition, previously reported local deposition characteristics for 1 mu m aerosols have also been considered. Computational two-phase models that have been evaluated include a standard chemical species (CS) mass fraction approximation, the drift flux (DF) approach to account for finite particle inertia, and two novel extensions of the DF model to correct for near-wall particle velocity. The first velocity correction model (DF-VC1) applies a continuous field solution for particle slip at the wall surface. As an alternative, a sub-grid near-wall Lagrangian solution has been proposed as the DF-VC2 model. Localized experimental results for the deposition of 400 nm particles indicated elevated deposition contours ranging from 1% to 5% of total deposition at the first bifurcation and 0.1-1% at the second. Of the computational models tested, the DF-VC2 method provided the best match to experimental deposition values on a regional and highly localized basis. Specifically, the DF-VC2 model matched total experimental deposition results to within 10% for both 400 nm and I Pm particles. Considering the local deposition of fine aerosols, the DF-VC2 model matched the experimentally determined elevated contours at the first and second bifurcations for both 400 nm and 1 mu m, particles. In conclusion, a DF particle transport model with near-wall velocity corrections appears to provide a highly effective solution for the deposition of fine respiratory aerosols. (C) 2007 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据