4.6 Article

First-in-Human Evaluation of a Novel Robotic-Assisted Coronary Angioplasty System

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 4, 期 4, 页码 460-465

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2010.12.007

关键词

angioplasty; robotic-assisted PCI; robotics

向作者/读者索取更多资源

Objectives We aimed to evaluate the safety and feasibility of a robotic angioplasty system in delivery and manipulation of coronary guidewires, balloons, and stents in patients undergoing elective percutaneous coronary intervention (PCI). Background A remote-control, robotic-assisted angioplasty system is under development to address some of the procedural challenges and occupational hazards associated with traditional PCI. Methods Patients with coronary artery disease and clinical indication for elective PCI were enrolled. The coronary angioplasty procedure was performed with the CorPath 200 robotic system (Corindus, Inc., Natick, Massachusetts). The system consists of a remote interventional cockpit and a multicomponent bedside unit that enables the operator to advance, retract, and rotate guidewires and rapid exchange catheters. The primary endpoint was device clinical success (<= 30% residual stenosis) without in-hospital major adverse cardiac events. Technical success was defined as the ability of the system to complete all the planned angioplasty steps on the basis of procedural segments. Patients were followed up to 30 days after angioplasty procedure. Results A total of 8 patients were enrolled in the study. The primary endpoint was achieved in all patients (100%). The technical success of the robotic system was 97.9% in completing 47 of 48 planned steps. There were no device- or procedure-related complications and no in-hospital or 30-day major adverse cardiac events. The operators rated the robotic system performances as equal to or better than manual procedures in 97.5% of the cases. The operator radiation exposure was 97% lower than the levels found at the standard table position. Conclusions Early clinical experience with a robotic-assisted angioplasty system demonstrated feasibility, safety, and procedural effectiveness comparable to manual operation. In addition, the total operator exposure to radiation was significantly low. A larger study is warranted to verify the safety and effectiveness of robotic-assisted percutaneous coronary intervention. (J Am Coll Cardiol Intv 2011;4:460-5) (C) 2011 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据