4.6 Article

Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 3, 期 2, 页码 233-243

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2009.11.015

关键词

calcification; procedural success; transcatheter aortic valve implantation

向作者/读者索取更多资源

Objectives The aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI). Background Transcatheter aortic valve implantation is a new percutaneous technique especially for elderly, high-risk patients with significant aortic valve stenosis (AS). After TAVI, post-interventional paravalvular aortic regurgitations (PAR) can occur, which is believed to be related partially to valve calcifications. Methods We prospectively analyzed 100 symptomatic patients with severe AS scheduled for TAVI with the CoreValve ReValving (Medtronic, Minneapolis, Minnesota) prosthesis. In all patients, a native and contrast-enhanced multislice cardiac computed tomography was performed pre-interventionally. Calcification load of the valve and the adjacent outflow tract was estimated by the Agatston Score (AgS), and the amount and distribution of calcification was semi-quantitatively assessed and graded on a 1 to 4 scale (device landing zone calcification score [DLZ-CS]). Aortography was performed to evaluate the PAR pre-interventionally, after initial device release (PAR0) and after termination of the procedure (PAR1). Transthoracic echocardiography was performed 2 weeks after implantation (PAR2). Results The AgS and DLZ-CS showed a significant correlation with the grade of PAR0 (AgS: r = 0.329, p = 0.001; DLZ-CS: r = 0.356, p < 0.001), PAR1 (AgS: r = 0.254, p = 0.011; DLZ-CS: r = 0.240, p = 0.016), and PAR2 (AgS: r = 0.341, p = 0.001; DLZ-CS: r = 0.300, p = 0.002). Both scores (AgS and DLZ-CS) showed a significant positive correlation (r = 0.858, p < 0.001). Conclusions Calcification in the CoreValve device landing zone shows a significant positive correlation to PAR after TAVI. Furthermore, the need for second maneuvers (i.e., post-dilation after initial device release) can be predicted by these calcification scores (AgS and DLZ-CS). (J Am Coll Cardiol Intv 2010;3:233-43) (C) 2010 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据