4.6 Article

Long-Term Safety and Efficacy With Paclitaxel-Eluting Stents 5-Year Final Results of the TAXUS IV Clinical Trial (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent)

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 2, 期 12, 页码 1248-1259

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2009.10.003

关键词

coronary artery stent; long-term; randomized controlled trial; restenosis; TAXUS; thrombosis

资金

  1. Boston Scientific Corporation
  2. Cordis

向作者/读者索取更多资源

Objectives The pivotal TAXUS IV (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent) trial evaluated the long-term safety and effectiveness of the paclitaxel-eluting stent (PES) compared with an otherwise identical bare-metal stent (BMS) in a relatively uncomplicated population of patients with a single de novo lesion in a native coronary vessel, treated between March and July 2002. Background Long-term follow-up is required to determine whether the early safety and efficacy of drug-eluting stents are maintained. Methods The primary end point of this prospective, randomized, double-blind trial was 9-month ischemia-driven target vessel revascularization (TVR) for IDES versus the BMS control. Follow-up was complete in 1,230 (95.1%) of 1,294 randomized evaluable patients at 5 years. Results Compared with BMS, PES significantly reduced TVR at 9 months (12.1% vs. 4.7%; p < 0.0001); this benefit was maintained through 5 years (27.4% vs. 16.9%; p < 0.0001), given comparable TVR rates for BMS and PES between years 1 and 5 (4.1%/year vs. 3.3%/year; respectively, p = 0.16). Similar patterns were observed for composite major adverse cardiac events (MACE) (32.8% BMS vs. 24.0% PES, p = 0.0001 at 5 years). Stent thrombosis was comparable for PES and BMS at 9 months (0.8% BMS vs. 0.8% IDES; p = 0.98) and at 5 years (2.1% BMS vs. 2.2% PES, p = 0.87). The overall revascularization benefits of IDES were consistent across multiple subgroups, including sex, diabetes, left anterior descending artery lesion location, reference vessel diameter, lesion length, and multiple stents. Conclusions These 5-year results demonstrate the long-term safety and sustained efficacy of IDES compared with BMS in patients with noncomplex lesions. (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent; NCT00292474) (J Am Coll Cardiol Intv 2009;2:1248-59) (C) 2009 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据