4.6 Article

Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Derived Parameters

期刊

INVESTIGATIVE RADIOLOGY
卷 44, 期 12, 页码 769-775

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0b013e3181b62271

关键词

IVIM; diffusion; perfusion; pancreatic cancer

向作者/读者索取更多资源

Objectives: To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory. Materials and Methods: Twenty-three patients with pancreas carcinoma and 14 volunteers with healthy pancreas were examined at 1.5 Tesla using a single-shot echo-planar imaging DWI pulse sequence. Eleven b-values ranging from 0 to 800 s/mm(2) were used. The acquisition was separated into blocks (b(0), b(25)), (b(0), b(50)), ... (b(0), b(800)) and each block was acquired in a single expirational breath-hold (TA = 26 seconds) to avoid motion artifacts. The ADC was calculated for all b-values using linear regression yielding ADC(tot). By applying the IVIM model, which allows for the estimation of perfusion effects in DWI, the perfusion fraction f and the perfusion free diffusion parameter D were calculated. The diagnostic performance of ADC, f and D as a measure for the differentiation between healthy pancreas and pancreatic carcinoma was evaluated with receiver operating characteristics analysis. Results: In the healthy control group, the ADC,., ranged from 1.53 to 2.01 mu m(2)/ms with a mean value of 1.71 +/- 0.19 mu m(2)/ms, the perfusion fraction f ranged from 18.5% to 40.4% with a mean value of 25.0 +/- 6.2%, and the diffusion coefficient D from 0.94 to 1.28 mu m(2)/ms with a mean value of 1.13 +/- 0.15 mu m(2)/ms. In patients with pancreas carcinoma, the ADC(tot) ranged from 0.98 to 1.81 mu m(2)/ms with a mean value of 1.31 +/- 0.24 mu m(2)/ms, the perfusion fraction f ranged from 0% to 20.4% with a mean value of 8.59 +/- 4.6% and the diffusion coefficient D from 0.74 to 1.60 mu m(2)/ms with a mean value of 1.15 +/- 0.22 mu m(2)/ms. In comparison to healthy pancreatic tissue, a significant reduction of the perfusion fraction f and of ADC(tot) was found in pancreatic carcinoma (P < 0.00001, 0.0002, respectively). The f value showed more than a 10-fold higher significance level in distinguishing cancerous from normal tissue when compared with the ADC,,, value. No significant difference in the diffusion coefficient D was observed between the 2 groups (P > 0.5). In the receiver operating characteristic-analyses, the area under curve for f was 0.991 and significantly larger than ADC(tot) (P < 0.05), f had the highest sensitivity, specificity, negative predictive value, and positive predictive value with 95.7%, 100%, 93.3%, and 100%, respectively. Conclusions: Using the IVIM-approach, the f value proved to be the best parameter for the differentiation between healthy pancreas and pancreatic cancer. The acquisition of several b-values strongly improved the stability of the parameter estimation thus increasing the sensitivity and specificity to 95.7% and 100% respectively. The proposed method may hold great promise for the non invasive, noncontrast-enhanced imaging of pancreas lesions and may eventually become a screening tool for pancreatic cancer.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据