Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography

期刊

INVESTIGATIVE RADIOLOGY
卷 44, 期 1, 页码 1-6

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0b013e31818c3d4b

关键词

dual energy CT (DECT); image fusion; contrast enhancement; signal-to-noise ratio (SNR); image quality

向作者/读者索取更多资源

Objective: The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in:dual energy computed tomography (DECT) angiography. Material and Methods: Fifteen patients underwent a CT angiography of the aorta with a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) in dual energy mode (DECT) (tube voltage: 80 and 140 kVp; tube current: 297 eff. mA. and 70 eff. mA; collimation, 14 x 1.2 min). Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.1, 0.3, 0.5, 0.7, 0.9, and 1.0) generating different ratios between the 80- and 140-kVp images (eg, factor 0.5 corresponds to 50% image information from the 140- and the 80-kVp image). Both CT values and SNR were measured in the descending aorta (levels of celiac trunk, renal arteries, and aortic bifurcation), in the right and left common iliac artery and in paraaortal fat. Image quality was evaluated using a 5-point grading scale. Results were compared using paired t-tests and nonparametric paired Wilcoxon tests. Results: Statistically significant increases in mean CT values were seen in vessels when increasing weighting factors were used (all P <= 0.001). For example, mean CT values derived from the aorta at the level of the celiac trunk were 273.8 +/- 25.8 Hounsfield units (HU), 304.0 +/- 24.3 HU, 361.4 +/- 22.5 HU, 418.3 +/- 25.8 HU, 477.8 +/- 32.2 HU, 536.2 +/- 41.2 HU, 564.6 +/- 45.3 HU, when the weighting factors 0.0, 0.1, 0.3, 0.5, 0.7, 0.9, and 1.0 were used. The highest SNR values were found in vessels when the weighting factor 0.5 was used. The highest SNR values of the paraaortal fat were obtained for the weighting factors 0.3 and 0.5. Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0.5. Conclusion: Different weighting factors used to create fused images in DECT cause statistically significant differences in CT value, SNR, and image quality. Best results were obtained using the weighting factor 0.5, which we recommend for image fusion in DECT angiography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据