4.6 Article

A Combined High Temporal and High Spatial Resolution 3 Tesla MR Imaging Protocol for the Assessment of Breast Lesions Initial Results

期刊

INVESTIGATIVE RADIOLOGY
卷 44, 期 9, 页码 553-558

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0b013e3181b4c127

关键词

breast imaging; high field magnetic resonance imaging; MR mammography; breast cancer; 3 Tesla

向作者/读者索取更多资源

Purpose: To develop a 3.0 Tesla breast imaging protocol that combines high temporal and spatial resolution three-dimensional MR sequences for quantitative time course and morphologic analysis of breast lesions. Materials and Methods: Thirty-four patients were included in the study (age range, 31-82; mean age, 54.3). The study protocol was approved by the Institutional Review Board and written informed consent was obtained from all patients. The magnetic resonance imaging protocol included: a coronal T1-weighted volume-interpolated-breathhold-examination sequence, focused on high temporal resolution for optimal assessment of the contrast-enhancement behavior of lesions (SI 1.7 mm isotropic; TA 3.45 minutes for 17 measurements); a coronal T1-weighted turbo fast-low-angle-shot-three-dimensional sequence, with water-excitation and fat suppression, focused oil high spatial resolution for morphologic analysis (SI 1 mm isotropic; TA 2 minutes); and a repeated coronal volume-interpolated-breathhold-examination sequence for detection of washout. Lesion size and morphology were assessed. Region-of-interests for suspicious areas were manually drawn and evaluated for contrast-enhancement behavior by plotting intensity courses against time. Sensitivity and specificity with a 95% confidence interval and the negative predictive value and positive predictive value were calculated. Diagnostic accuracy was assessed. The histopathological diagnoses were used as a standard of reference. Results: Fifty-five lesions were detected in 34 patients. All malignant breast lesions were identified correctly. There were 5 false-positive lesions. The sensitivity of contrast-enhanced magnetic resonance imaging of the breast at 3 T was 100%, with a 95% confidence interval (CI) of 90.6% to 100%. The specificity was 72.2%, with a 95% CI of 49.1% to 87.5%. The positive predictive value was 0.88 and the negative predictive value was 1. Diagnostic accuracy was 91% with a 95% CI of 80.4% to 96.1%. Conclusion: Our prospective study demonstrates that the presented 3 Tesla MR imaging protocol, comprising both high temporal and high spatial resolution, enables accurate detection and assessment of breast lesions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据