4.7 Article

Flow boiling of ammonia in vertical small diameter tubes: Two phase frictional pressure drop results and assessment of prediction methods

期刊

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2011.11.018

关键词

Two phase; Pressure drop; Ammonia; Experimental study

资金

  1. Higher Education Commission Pakistan [HEC]

向作者/读者索取更多资源

Two phase pressure drops were measured for ammonia at a wide range of test conditions in two sizes of vertical mini channels. The test sections were made of stainless steel (AISI 316) tubes with internal diameter of 1.70 mm and 1.224 mm and a uniformly heated length of 245 mm. Experiments were conducted at three saturation temperatures of 23 degrees C, 33 degrees C and 43 degrees C, the heat flux ranging from 15 to 355 kW/m(2) and the mass flux ranging from 100 to 500 kg/m(2)s. The effect of the heat flux, the mass flux, the vapour quality, the saturation temperature and the internal diameter on the two phase pressure drop are presented in this article. Some generalized two phase pressure drop correlations suggested for macro and micro scale channels are examined by comparing them with our experimental data. None of the examined correlations agreed well with the test data. A new correlation (modified form of Tran et al. correlation) is proposed which is able to predict the experimental data with MAD of 16% and 86% of the data is within +/-30% range. (C) 2011 Elsevier Masson SAS. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据