4.4 Article

The Effect of Isokinetic Testing Speed on the Reliability of Muscle Fatigue Indicators During a Hip Abductor-Adductor Fatigue Protocol

期刊

INTERNATIONAL JOURNAL OF SPORTS MEDICINE
卷 34, 期 7, 页码 646-653

出版社

GEORG THIEME VERLAG KG
DOI: 10.1055/s-0032-1321801

关键词

intraclass correlation coefficient; standard error of measurement; functional ankle instability; fatigue index; percent decrease in performance; slope of the regression equation

向作者/读者索取更多资源

The aim of this study was to investigate the reliability of fatigue indicators calculated from peak torque and total work during isokinetic speeds of 60, 90, 120 and 180 degrees . s(-1) during a hip fatigue protocol. 10 males suffering from a history of unilateral functional ankle instability and 10 male healthy controls performed 5 maximal concentric contractions on an isokinetic dynamometer. Following a 4 min rest period subjects were instructed to perform repeated maximal concentric contractions to fatigue, which was defined as 3 consecutive repetitions below 50% of the maximum peak torque value. Each testing speed was randomised with 24 h between speeds. The subjects were asked to return to the laboratory 7 days later to repeat the 4 speeds, with 24 h between speeds. Muscle fatigue was determined for each testing speed by the fatigue index, the percent decrease in performance and the slope of the regression equation. The most reliable fatigue determination method was the slope of the regression equation, when testing at a speed of 120 degrees . s(-1). It is recommended that future investigators examine and plot their data before choosing the slope of the regression equation as their fatigue indicator, as a linear model is required.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据