4.5 Article

Investigation of a novel ejector expansion refrigeration system using the working fluid R134a and its potential substitute R1234yf

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2014.05.021

关键词

Ejector; Efficiency; R134a; R1234yf; Modeling; Two-phase flow

向作者/读者索取更多资源

To overcome the constraints related to the steady-state operation of the ejector and the separator in a basic ejector-expansion refrigeration system, a new refrigeration system with two evaporators using an ejector as a throttling valve is presented. A constant-area mixing model for the ejector requiring a small number of data and assumptions was established to perform a thermodynamic cycle analysis of the new system. The effects of the ejector area ratio and the condenser temperature on the performance of the ejector and therefore on the increase in COP of the new system compared to the conventional bi-evaporator refrigeration system were investigated for the same cooling capacities of the two evaporators. The refrigerants R134a and its substitute R1234yf were tested. It was found that the novel system has an important improvement in COP for both R134a and R1234yf. This increase in COP is higher for R1234yf especially at high condensing temperatures. (C) 2014 Elsevier Ltd and IIR. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据