4.5 Article

Experimental and numerical results of a high frequency rotating active magnetic refrigerator

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2013.09.002

关键词

Active magnetic regenerator; Magnetic refrigeration; Experiment; Numerical modelling; Parasitic losses analysis

资金

  1. Programme Commission on Energy and Environment (EnMi) [2104-06-0032]
  2. Danish Council for Strategic Research
  3. CNPq (Brazil) through (National Institute of Science and Technology in Cooling and Thermophysics) [18573581/2008-8]
  4. Danish Council for Independent Research|Technology and Production Sciences [10-092791]

向作者/读者索取更多资源

Experimental results for a recently developed prototype magnetic refrigeration device at the Technical University of Denmark (DTU) were obtained and compared with numerical simulation results. A continuously rotating active magnetic regenerator (AMR) using 2.8 kg packed sphere regenerators of gadolinium (Gd) was employed. With operating frequencies up to 10 Hz and volumetric flow rates up to 600 L h(-1), the prototype has shown high performance and the results are consistent with predictions from numerical modelling. Magnetocaloric properties of the Gd spheres were obtained experimentally and implemented in a one-dimensional numerical AMR model that includes also the parasitic losses from the prototype. The temperature span for a thermal load of 200 W as a function of frequency was measured and modelled. Moreover, the temperature span dependence on the cooling capacity as a function of cycle frequency was determined. A detailed study of these parasitic losses was carried out experimentally and numerically. (C) 2013 Elsevier Ltd and IIR. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据