期刊
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
卷 34, 期 3, 页码 732-741出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2010.12.005
关键词
Carbon dioxide; Transcritical cycle; Expansion; Device; Energy recovery; Friction
资金
- National Natural Science Foundation of China [50706035]
The loss of contact between the vane tip and cylinder wall was proven to cause a serious leakage and inefficient operation of the rotary vane expander, which was developed to replace the throttling valve in the trans-critical CO2 refrigeration system. An improved structure was suggested by introducing high-pressure gas into the vane slots. This paper presents the experimental investigation of the improved prototype expander. By comparing the improved prototype with the original, focusing on the expander performance and the p-theta diagram as well as the vane movement, the effects of introducing high-pressure gas into the slots on the thermodynamic processes and performance were analyzed. The results showed that, by introducing the high-pressure gas into the vane slots, the volumetric efficiency was increased from 17% to 35%, and the isentropic efficiency improved from 15% to 45%, resulting in a maximum COP improvement of 27.2% compared to the throttling cycle under the same working conditions. (c) 2010 Elsevier Ltd and IIR. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。