4.7 Article

Deuterium permeation and isotope effects in nickel in an elevated temperature range of 450-850 °C

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 39, 期 24, 页码 12789-12794

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2014.06.038

关键词

Permeation; Deuterium; Hydrogen; Nickel; Nuclear hydrogen; Nuclear fusion

资金

  1. National R&D Program through a National Research Foundation of Korea (NRF) grant - MSIP: Ministry of Science ICT & Future Planning [2008-0061900, 2013035961]

向作者/读者索取更多资源

A series of deuterium permeation experiments were carried out using a nickel membrane in an elevated temperature range of 450-850 degrees C for application to nuclear fusion and nuclear hydrogen technologies. A complete set of permeability, diffusivity, and solubility data for deuterium in nickel was successfully determined. The results of this study were compared with results previously reported by other authors. The results for deuterium were also compared with the results for hydrogen to estimate the isotope effect. The results for and a discussion of deuterium permeation and the isotope effects in nickel are presented. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.