期刊
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 39, 期 26, 页码 14212-14221出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2014.02.096
关键词
Hydrogen; Electrochemical impedance spectroscopy (EIS); Current interrupt (CI); Current mapping (CM); Proton exchange membrane (PEM); Electrolyser
Electrochemical impedance spectroscopy (EIS), current interrupt (CI) and current mapping (CM) were investigated as in-situ characterisation tools for PEM electrolysers. A 25 cm(2) cell with titanium anode and carbon cathode plates were utilised in this study. A commercial MEA consisting of 1 mg IrO2/cm(2) on the anode and 0.3 mg Pt/cm(2) on the cathode was used. The electrocatalyst was deposited on Nafion (R) membranes. The electrochemical losses in a PEM electrolyser namely: activation, ohmic and mass transfer losses were identified using EIS and CI and both the advantages and disadvantages of the methods were discussed. The current distribution over the membrane electrode assembly (MEA) at different current densities was measured using the current mapping method. It is also shown that under the given experimental conditions the current density decreases along the serpentine flow field. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据