4.7 Article

Experimental characterization methodology for the identification of voltage losses of PEMFC: Applied to an open cathode stack

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 37, 期 8, 页码 7309-7315

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2011.11.130

关键词

Activation losses; Mass transport losses; Ohmic losses; PEMFC; Open cathode

资金

  1. CICYT [DPI2010-15274 MICINN, DPI2011-25649 MICINN]

向作者/读者索取更多资源

The objective of this study is to describe the methodology used to isolate the main voltage loss indicators through a simple and effective treatment of a current interrupt and current sweep. The voltage loss indicators are activation polarization, mass transport, and ohmic losses. The indicators for these losses are the Tafel slope, mass transport resistance and ohmic resistance respectively. The use of this methodology to isolate the individual voltage losses works quite well. Even though there may be some inaccuracies, the trends can be clearly seen. This methodology can be used in any PEMFC system to monitor the state of health of the fuel cell. If this method were to be automated and implemented on a periodic basis, then an on-line measurement of the individual voltage losses could be monitored. The data analysis indicates that a major objective of the controller will be to minimize the mass transport losses by implementing proper temperature control. Copyright (c) 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据