4.7 Article Proceedings Paper

Identification of failed cells inside PEMFC stacks in two cases: Anode/cathode crossover and anode/cooling compartment leak

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 35, 期 7, 页码 2772-2776

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2009.05.015

关键词

PEM fuel cell; Reliability; Diagnosis; Leakage

向作者/读者索取更多资源

Various PEMFC operating conditions can lead to irreversible damages as membrane break and gasket deterioration. If leak check procedures can highlight the lack of tightness in fuel cells, they are not appropriate to inform actually where the fault has occurred in the stacks. Thus, diagnosis procedures allowing the failed cells to be identified are needed. Then, these cells can be removed and replaced by safe ones. The article presents some descriptions of aged assemblies subjected to anode/cathode crossover and anode/cooling compartment leakage. Some experimental investigations are carried out with the goal to locate the defective cells. The open current voltages of the cells are monitored and analysed in different operating conditions. Experimental procedures combined with data analysis tools allow the detection of the failed cells, which show abnormal performance and voltage pattern when they are compared to the other safe cells. (C) 2009 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据