4.7 Article

Experimental investigation on window ejected facade flame heights with different constraint side wall lengths and global correlation

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2014.06.060

关键词

Compartment fire; Side wall length; Facade; Flame height; Window; Global parameter

资金

  1. National Nature Foundation of China [51176180]
  2. National Basic Research Program of China [2012CB719702]
  3. Fundamental Research Funds for the Central Universities

向作者/读者索取更多资源

This paper presents an experimental investigation on the effect of side wall length (normal to the facade direction) on the ejected facade flame height from a window of an under-ventilated compartment fire. The ejected facade flames are recorded by a CCD camera with various side wall lengths L at different side wall separation distances D. Results show that, as the length of the side wall increases, the change in behavior of the flame height can be categorized into two regimes: (1) the flame-entrainment-controlled regime in which flame height increases with side wall length for (half) axisymmetric fire but independent of side wall length for wall fire; and (2) the combustion-efficiency-controlled regime where the flame heights for both these two fire types decrease with side wall length due to decrease of the combustion efficiency inside the fire room, for L = 3D or greater. A global parameter K is then proposed based on scaling analysis for the air entrainment of the flame with side wall length, in relation to characteristic length scales l(1) and l(2) of the window, which well collapse the experimental data for different window dimensions, side wall lengths and separation distances. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据