期刊
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
卷 62, 期 -, 页码 142-152出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2013.02.067
关键词
Critical heat flux (CHF); Visualization; Narrow heating surface; Horizontal pool; Saturated water
资金
- National Research Foundation of Korea (NRF)
- Korea government (MEST) [2012M2A8A4004176]
- National Research Foundation of Korea [2012M2A8A4026026] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
A visualization study was performed to identify the near-surface boiling structure and critical heat flux (CHF) triggering mechanism in a horizontal pool boiling of saturated water using a narrow transparent ITO heating surface. Total reflection and diagonal inside view techniques were applied in a synchronized manner. Contrary to the common postulation that a thin liquid film exists under a coalesced massive bubble, the base of a coalesced massive bubble is almost dry under the conditions studied. Approaching the CHF, a small dry area is left on a boiling surface at the departure of the coalesced massive bubble. Rather than being wetted, the small residual dry area expands to a large dry area if the bubble nucleation around the residual dry area is sufficiently vigorous. This re-expansion repeats throughout consecutive departures of coalesced massive bubbles as wall superheat further increases. Then, a certain part of the residual dry area is not wetted for a sufficient time and evolves into an irreversible hot spot, leading to a boiling crisis. (C) 2013 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐