资金
- Defense Advanced Research Project Agency (DARPA)
- Space and Naval Warfare Systems Center (SPAWARS-YSCEN), San Diego, CA [N66001-08-C-2007]
We design and test a low thermal/hydraulic resistance, multi-artery heat-pipe spreader vapor chamber. Liquid (water) is supplied to a highly concentrated heat-source region through a monolayer evaporator wick and a set of lateral converging arteries, fabricated from sintered, spherical copper particles. The monolayer wick allows for a minimum evaporator resistance of 0.055 K/(W/cm(2)), which is related to a critical transition where the receding meniscus approaches the particle neck. Similar behavior is also observed in a monolayer-wick evaporator, partially submerged in liquid bath. After this minimum, local dryout occurs and increases the resistance. However, a continuous liquid supply through the lateral arteries does not allow for total dryout in the test limit of 580 W/cm(2). These thermal/hydraulic behaviors are predicted using the local thermal equilibrium and nonequilibrium models. (C) 2011 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。