4.7 Article

The measurement of heat transfer from hot surfaces to non-wetting droplets

期刊

INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
卷 54, 期 7-8, 页码 1432-1440

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2010.11.051

关键词

Infrared; Non-wetting droplets; Cooling

资金

  1. EPSRC [EP/C549465/1]

向作者/读者索取更多资源

An experimental method to measure the heat transfer between a hot surface and a non-wetting droplet is reported in this paper. By means of transient, high resolution, infrared microscopy, surface temperature measurements with spatial and temporal resolutions of similar to 100 mu m and similar to 4 ms, respectively, are obtained, by observing a thin metallic layer from beneath through an infrared-transparent substrate. Data from the infrared camera is generated at each time-step in the form of a set of temperatures, at closely-spaced locations on the surface of the infrared transparent plate. Subsequent solution of the transient thermal conduction equation within the substrate permits all thermal quantities (heat flux, energy, etc.) to be determined. As a typical result, the heat transferred by a 1.5 mm droplet is measured to be 0.191 with the heat flux peaking at 3.5 MW/m(2) during the 10 ms it spends in the vicinity of the surface, and with a peak transient surface temperature reduction of 47 degrees C. Error analysis indicates that the uncertainty in this measurement of heat transfer is about 15%. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据