4.7 Article

Experimental study of biporous wicks for high heat flux applications

期刊

INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
卷 52, 期 21-22, 页码 5113-5121

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2009.05.005

关键词

Biporous wick; Electronics cooling; Heat pipe wick; High heat fluxes; Monoporous wick

资金

  1. U.S. Navy/Office of Naval Research
  2. [N00014-04-1-0280]

向作者/读者索取更多资源

Biporous; wicks are wicks with two distinguished characteristic pore sizes while monoporous; wicks are wicks with a single characteristic pore size. in this work three monoporous and 19 biporcrus wicks were tested. Thermophysical properties for the biporous wicks were measured. Thin biporcrus wicks distinguish from thick biporous wick by mechanism of heat transfer that occurs inside the wick. Thin biporous wicks remove heat similar to monoporous wicks by evaporation from menisci formed inside pores at liquid-vapor-solid interfaces. Thin biporous wicks were found to reach higher critical heat flux (CHF) than monoporous wicks because they develop evaporating menisci not only on top surface of the wick but also inside the wick. Thick biporous wicks were found to reach even higher CHF than thin biporous wicks because they continue to operate although the vapor blanket (film boiling) exists on the heated surface. This is possible because the top layer of the wick continues to supply liquid to the evaporating menisci above the vapor blanket region and vapor jets form between large pores of the wick and vent the vapor out of the wick. It was also found that for thick biporous wicks operating at very high heat fluxes, the heat conducts radially into the wick. The best monoporous wick tested had CHF at 300 W/cm(2) (21 degrees C superheat), the best thin biporous wick tested had CHF at 520 W/cm(2) (50 degrees C superheat), and the best thick biporous wick tested had CHF at 990 W/cm(2) (147 degrees C superheat). Thick biporous wicks can be used for 600-1000 W/cm(2) applications where high superheats and heat spreading into the wick are acceptable. For applications below 600 W/cm(2) are recommended thin biporous wicks and for applications below 300 W/cm(2) are recommended monoporous wicks. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据