期刊
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY
卷 132, 期 2-3, 页码 162-166出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.ijfoodmicro.2009.04.017
关键词
Water dispensers; Peracetic acid; Hydrogen peroxide; P. aeruginosa; S. maltophilia
资金
- Ministry of University and Scientific Research
The abilities of peracetic acid and hydrogen peroxide to remove or reduce Pseudomonas aeruginosa and Stenotrophomonas maltophilia in output water from microfiltered water dispensers (MWDs) were investigated. Two MWDs were inoculated with strains of P aeruginosa and S. maltophilia isolated from water. Dispensers A and B were disinfected with 10% (v/v) peracetic acid (PAA) and 3% (v/v) hydrogen peroxide (HP) respectively. Each dispenser was disinfected three times at monthly intervals with contact times of 10, 30 and 40 min. Water dispensed by the MWDs was collected immediately before and after each treatment and then twice weekly for the remaining period. Once a week a sample of the tap water entering the dispensers was tested. P. aeruginosa and S. maltophilia were enumerated in the 90 samples collected during 6 months. In the output water from the dispensers before the first treatment, the number of the bacteria was 3 to 4 log cfu/100 mL. Treatment with PAA greatly reduced the numbers of P. aeruginosa and S. maltophilia in the dispensed water initially. However, by 2 days after treatment, the numbers increased and remained high. In the case of disinfection with HP for 40 min, P. aeruginosa was not detected in most of the samples (73.7%). Numbers of S. maltophilia decreased with increasing time after treatment. (C) 2009 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据