4.5 Article

Arsenite removal from water by electro-coagulation on zinc-zinc and copper-copper electrodes

出版社

SPRINGER
DOI: 10.1007/s13762-012-0113-z

关键词

Arsenic removal; Electro-chemical method; Eco-friendly; Ground water

资金

  1. University Grant Commission (UGC), New Delhi, India

向作者/读者索取更多资源

Removal of arsenite from aqueous solution was carried out using electro-coagulation method. The experiments were conducted using copper-copper and zinc-zinc electrodes. The optimized experimental parameters were 2.0 mg/L initial concentration, 16.0-min processing time, 6.0 pH, 3.0-V applied voltage and 30 A degrees C temperature for zinc-zinc electrodes while these values for copper-copper electrodes were 2.0 mg/L initial concentration, 20.0-min processing time, 7.0 pH, 5.0-V applied voltage and 30 A degrees C temperature. The results demonstrated that zinc-zinc and copper-copper electrodes removed arsenite up to 99.89 and 99.56 %, respectively. The treated water was clear, colorless and odorless without any secondary contamination. There was no change in water quality after the removal of arsenite. The reported method is capable to remove arsenite from water at 6-7 pH range, which is a pH range of natural water. Therefore, this method may be the choice of arsenite removal from natural ground water.