4.6 Article

Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner

期刊

INTERNATIONAL JOURNAL OF CARDIOLOGY
卷 274, 期 -, 页码 382-387

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2018.09.010

关键词

-

向作者/读者索取更多资源

Aims: To evaluate image quality, interpretability, diagnostic accuracy and radiation exposure of coronary CT angiography (CCTA) performed with a new scanner equipped with 0.23-mm spatial resolution, new generation iterative reconstruction, 0.28-second gantry rotation time and intra-cycle motion-correction algorithm in consecutive patients with coronary stents, including those with high heart rate (HR) and atrial fibrillation (AF). Materials and methods: We enrolled 100 consecutive patients (85 males, mean age 65 +/- 10 years) with previous coronary stent implantation scheduled for clinically indicated non-emergent invasive coronary angiography (ICA). Image quality, coronary interpretability and diagnostic accuracy vs. ICA were evaluated and the effective dose (ED) was recorded. Results: Mean HR during the scan was 67 +/- 13 bpm. Twenty-six patients had >65 bpm HR during scanning and 13 patients had AF. Overall, image quality was high (Likert = 3.2 +/- 0.9). Stent interpretability was 95.8% (184/192 stents). Among 192 stented segments, CCTA correctly identified 22 out of 24 with >50% in-stent restenosis (ISR) (sensitivity 92%). In a stent-based analysis, specificity, positive and negative predictive values and diagnostic accuracy for ISR detection were 91%, 99%, 60% and 91%, respectively. In a patient-based analysis, CCTA diagnostic accuracy was 85%. Overall, mean ED of CCTA was 2.4 +/- 1.2 mSv. Conclusions: Awhole-organ CT scanner was able to evaluate coronary stents with good diagnostic performance and low radiation exposure, also in presence of unfavorable HR and heart rhythm. Translational aspect: The present study is the first to evaluate the CCTA capability of detecting in-stent restenosis in consecutive patients, including those with high HR and AF, using a recent scanner generation that combines improved spatial and temporal resolution with wide coverage. Using the whole-organ high-definition CT scanner we obtained high quality images of coronary stents with good interpretability and diagnostic accuracy combined with low radiation exposure, even in patients with unfavorable HR or heart rhythm for CCTA evaluation. (c) 2018 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据