4.5 Article

Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System Preliminary Report of Prospective Hello Study

期刊

MEDICINE
卷 94, 期 49, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000002189

关键词

-

资金

  1. Central College Basic Scientific Research Business Expenses-Interdisciplinary Projects: Tongji University [1501219103]

向作者/读者索取更多资源

Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.358.70 years in Group A and 46.61 +/- 7.84 years in Group B (P=0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P>0.05). The puncture times were 1.19 +/- 0.48 in Group A and 6.03 +/- 1.87 in Group B (P<0.001). The fluoroscopic times were 14.03 +/- 2.54 in Group A and 25.19 +/- 4.28 in Group B (P<0.001). The preoperative location time was 4.67 +/- 1.41minutes in Group A and 6.98 +/- 0.94minutes in Group B (P<0.001). The operation time was 79.42 +/- 10.15minutes in Group A and 89.65 +/- 14.06minutes in Group B (P=0.002). The hospital stay was 2.77 +/- 0.95 days in Group A and 2.87 +/- 1.02 days in Group B (P=0.702). There were no significant differences in the complication rate between the 2 groups (P=0.386).The highlight of HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据