4.4 Article

Real-time simulation of surgery by reduced-order modeling and X-FEM techniques

出版社

WILEY-BLACKWELL
DOI: 10.1002/cnm.1491

关键词

real time; surgery; model order reduction; X-FEM

向作者/读者索取更多资源

This paper describes a novel approach for the simulation of surgery by a combined technique of model order reduction and extended finite element method (X-FEM) methods. Whereas model order reduction techniques employ globally supported (Ritz) shape functions, a combination with X-FEM methods on a locally superimposed patch is developed for cutting simulation without remeshing. This enables to obtain models with very few degrees of freedom that run under real-time constrains even for highly non-linear tissue constitutive equations. To show the performance of the technique, we studied an application to refractive surgery in the cornea. Copyright (c) 2012 John Wiley & Sons, Ltd.