4.6 Article

A fast GPU-based Monte Carlo simulation of proton transport with detailed modeling of nonelastic interactions

期刊

MEDICAL PHYSICS
卷 42, 期 6, 页码 2967-2978

出版社

WILEY
DOI: 10.1118/1.4921046

关键词

proton therapy; CUDA; GPU; Monte Carlo; nonelastic

向作者/读者索取更多资源

Purpose: Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a CPU-based proton transport MC with detailed modeling of elastic and nonelastic proton-nucleus collisions. Methods: Using the CUDA framework, the authors implemented CPU kernels for the following tasks: (1) simulation of beam spots from our possible scanning nozzle configurations, (2) proton propagation through CT geometry, taking into account nuclear elastic scattering, multiple scattering, and energy loss straggling, (3) modeling of the intranuclear cascade stage of nonelastic interactions when they occur, (4) simulation of nuclear evaporation, and (5) statistical error estimates on the dose. To validate our MC, the authors performed (1) secondary particle yield calculations in proton collisions with therapeutically relevant nuclei, (2) dose calculations in homogeneous phantoms, (3) recalculations of complex head and neck treatment plans from a commercially available treatment planning system, and compared with oEANT4.9.6p2/TOPAS. Results: Yields, energy, and angular distributions of secondaries from nonelastic collisions on various nuclei are in good agreement with the GEANT4.9.6p2 Bertini and Binary cascade models. The 3D-gamma pass rate at 2%-2 mm for treatment plan simulations is typically 98%. The net computational time on a NVIDIA GTX680 card, including all CPU CPU data transfers, is similar to 20 s for 1 x 10(7) proton histories. Conclusions: Our CPU-based MC is the first of its kind to include a detailed nuclear model to handle nonelastic interactions of protons with any nucleus. Dosimetric calculations are in very good agreement with oEANT4.9.6p2/TOPAS. Our MC is being integrated into a framework to perform fast routine clinical QA of pencil-beam based treatment plans, and is being used as the dose calculation engine in a clinically applicable MC-based IMPT treatment planning system. The detailed nuclear modeling will allow us to perform very fast linear energy transfer and neutron dose estimates on the CPU. (C) 2015 American Association of Physicists in Medicine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据