4.6 Article

Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

期刊

MEDICAL PHYSICS
卷 42, 期 9, 页码 5027-5034

出版社

WILEY
DOI: 10.1118/1.4927567

关键词

radiotherapy; OAR; head and neck; atlas segmentation

资金

  1. EPSRC [EP/H046410/1, EP/J020990/1, EP/K005278, EP/J500331/1]
  2. MRC [MR/J01107X/1]
  3. EU [FP7-ICT-2011-9-601055]
  4. NIHR Biomedical Research Unit (Dementia) at UCL
  5. National Institute for Health Research University College London Hospitals Biomedical Research Centre (NIHR BRC UCLH/UCL High Impact Initiative)
  6. Intelligent Imaging EPSRC Program grant [EP/H046410/1]
  7. UCLLeonard Wolfson Experimental Neurology Centre
  8. CASE studentship
  9. GE Healthcare
  10. Fundacao para a Ciencia e a Tecnologia (FCT) [SFRH/BD/76169/2011]
  11. ESF
  12. POPH/QREN
  13. EU
  14. Fundação para a Ciência e a Tecnologia [SFRH/BD/76169/2011] Funding Source: FCT
  15. EPSRC [EP/H046410/1, EP/J020990/1] Funding Source: UKRI
  16. MRC [MR/J01107X/1] Funding Source: UKRI
  17. Engineering and Physical Sciences Research Council [EP/J020990/1, EP/H046410/1] Funding Source: researchfish

向作者/读者索取更多资源

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel similarity and truth estimation for propagated segmentations (STEPS) compared to the traditional simultaneous truth and performance level estimation (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary. (C) 2015 American Association of Physicists in Medicine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据