4.7 Article

Thermohydraulics of turbulent flow through a round tube by a peripherally-cut twisted tape with an alternate axis

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.icheatmasstransfer.2010.03.005

关键词

Turbulent flow; Heat transfer enhancement; Twisted tape; Thermal performance factor

资金

  1. Thailand Research Fund (TRF)
  2. Thailand Toray Science Foundation (TTSF)

向作者/读者索取更多资源

The effect of peripherally-cut twisted tape with alternate axis (PT-A) on the fluid flow and heat transfer enhancement characteristic in a uniform heat flux circular tube has been experimentally investigated. Experiments were conducted using water as a testing fluid in a turbulent tube where the Reynolds number was varied from 5000 to 20,000. Peripherally-cut twisted tape (PT) and typical twisted tape (TT) were also tested in similar conditions, for comparison. Evidently, the heat transfer rates in the tube fitted with the PTA, PT and TT are respectively enhanced up to 184%, 102% and 57% of that in the plain tube. In the present Reynolds number range tested, the PT-A, PT and TT offer the maximum thermal performances at constant pumping power of 1.25, 1.11 and 1.02, respectively. In addition, the correlations of the Nusselt number, friction factor and thermal performance were developed for the tube equipped with the PT-A in terms of peripherally-cut tape width ratio (w/W). Reynolds number (Re) and Prandtl number (Pr). (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据