4.7 Article

Application of high porosity metal foams as air-cooled heat exchangers to high heat load removal systems

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.icheatmasstransfer.2009.03.001

关键词

Heat removal; Porous; Metal foam heat exchangers; Convection visualization; Heatlines; Laminar jet

向作者/读者索取更多资源

A numerical study has been conducted to investigate the fluid flow and heat transfer of an air-cooled metal foam heat exchanger under the high speed laminar jet confined by two parallel walls for which the range of the Reynolds number is 600-1000. Two independent numerical solvers were used and cross-validated being a FORTRAN code and the commercially available software CFD-ACE. The effects of local thermal non-equilibrium, thermal dispersion, porosity, and pore density on the heat transfer augmentation are examined for different Reynolds numbers. Application of energy flux vectors, for convection visualization, is also illustrated for a more comprehensive analysis of the problem. Finally, the performance of the metal foam heat exchanger is compared to that of conventional finned design. It is observed that the heat removal rate can be greatly improved at almost no excess cost. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据