4.2 Article

Surface crack detection by flash thermography on concrete surface

期刊

INSIGHT
卷 50, 期 5, 页码 240-243

出版社

BRITISH INST NON-DESTRUCTIVE TESTING
DOI: 10.1784/insi.2008.50.5.240

关键词

defects; image processing; infrared; thermography

向作者/读者索取更多资源

Cracking may impair the durability of concrete by allowing immigration of external aggressive agents; therefore, crack monitoring is always a vital part in building pathology. This study proposes to apply short-duration pulsed thermography - flash thermography (FT) - for surface crack detection. This method allows full-field and non-contact qualitative observation of thermal radiation from an object surface and is highly accepted in the aerospace industry. It is superior to the common practice of surface crack detection - visual inspection. The overall inspection time is reduced and hence maintenance costs lowered. During inspection, the inspected surface is excited with a heat-pulse of short duration (similar to 3 ins). Surface cracking is detected based on the difference in heat emission between cracks and intact region. The results show that FT can detect surface cracks with 0.5 mm to 1 mm crack width successfully but micro-cracks (0.1 mm-0.5 mm) can only be detected by adding water with FT In addition, this study also compared the performances of traditional Sobel and Canny edge detectors and a proposed shear image subtraction method, for crack detection. The results show that the sheared image subtraction method is significantly more effective than the other two edge detection techniques in identifting cracks.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据