4.7 Article

A modified method of vibration surveillance by using the optimal control at energy performance index

期刊

MECHANICAL SYSTEMS AND SIGNAL PROCESSING
卷 58-59, 期 -, 页码 41-52

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ymssp.2014.12.009

关键词

Vibration surveillance; Optimal control; Energy performance index; Acceleration feedback

资金

  1. Polish Ministry of Science and High Education [NN 503 147134]

向作者/读者索取更多资源

A method of vibration surveillance by using the optimal control at energy performance index has been creatively modified. The suggested original modification depends on consideration of direct relationship between the measured acceleration signal and the optimal control command. The paper presents the results of experiments and Hardwarein-the-loop simulations of a new active vibration reduction algorithm based on the energy performance index idea modified in such a way, that it directly utilises the acceleration feedback signal. Promising prospects towards real application of the modified method in case of the high speed milling are predicted as well. (C) 2015 Published by Elsevier Ltd.