4.4 Article

Outbreak of Carbapenem-Resistant Enterobacteriaceae at a Long-Term Acute Care Hospital: Sustained Reductions in Transmission through Active Surveillance and Targeted Interventions

期刊

INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY
卷 33, 期 10, 页码 984-992

出版社

CAMBRIDGE UNIV PRESS
DOI: 10.1086/667738

关键词

-

资金

  1. US Department of Health and Human Services
  2. Pinellas County Health Department
  3. Florida Department of Health

向作者/读者索取更多资源

OBJECTIVE. To describe a Klebsiella pneumoniae carbapenemase (KPC)-producing carbapenem-resistant Enterobacteriaceae (CRE) outbreak and interventions to prevent transmission. DESIGN, SETTING, AND PATIENTS. Epidemiologic investigation of a CRE outbreak among patients at a long-term acute care hospital (LTACH). METHODS. Microbiology records at LTACH A from March 2009 through February 2011 were reviewed to identify CRE transmission cases and cases admitted with CRE. CRE bacteremia episodes were identified during March 2009-July 2011. Biweekly CRE prevalence surveys were conducted during July 2010-July 2011, and interventions to prevent transmission were implemented, including education and auditing of staff and isolation and cohorting of CRE patients with dedicated nursing staff and shared medical equipment. Trends were evaluated using weighted linear or Poisson regression. CRE transmission cases were included in a case-control study to evaluate risk factors for acquisition. A real-time polymerase chain reaction assay was used to detect the bla(KPC) gene, and pulsed-field gel electrophoresis was performed to assess the genetic relatedness of isolates. RESULTS. Ninety-nine CRE transmission cases, 16 admission cases (from 7 acute care hospitals), and 29 CRE bacteremia episodes were identified. Significant reductions were observed in CRE prevalence (49% vs 8%), percentage of patients screened with newly detected CRE (44% vs 0%), and CRE bacteremia episodes (2.5 vs 0.0 per 1,000 patient-days). Cases were more likely to have received beta-lactams, have diabetes, and require mechanical ventilation. All tested isolates were KPC-producing K. pneumoniae, and nearly all isolates were genetically related. CONCLUSION. CRE transmission can be reduced in LTACHs through surveillance testing and targeted interventions. Sustainable reductions within and across healthcare facilities may require a regional public health approach. Infect Control Hosp Epidemiol 2012;33(10):984-992

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据