4.1 Article

Exposure Level and Distribution Characteristics of Airborne Bacteria and Fungi in Seoul Metropolitan Subway Stations

期刊

INDUSTRIAL HEALTH
卷 49, 期 2, 页码 242-248

出版社

NATL INST OCCUPATIONAL SAFETY & HEALTH, JAPAN
DOI: 10.2486/indhealth.MS1199

关键词

Seoul; Subway station; Airborne bacteria; Airborne fungi; Underground

向作者/读者索取更多资源

The exposure level and distribution characteristics of airborne bacteria and fungi were assessed in the workers' activity areas (station office, bedroom, ticket office and driver's seat) and passengers' activity areas (station precinct, inside the passenger carriage, and platform) of the Seoul metropolitan subway. Among investigated areas, the levels of airborne bacteria and fungi in the workers' bedroom and station precincts were relatively high. No significant difference was found in the concentration of airborne bacteria and fungi between the underground and above ground activity areas of the subway. The genera identified in all subway activity areas with a 5% or greater detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium for airborne bacteria and Penicillium, Cladosporium, Chrysosporium, Aspergillus for airborne fungi. Staphylococcus and Micrococcus comprised over 50% of the total airborne bacteria and Penicillium and Cladosporium comprised over 60% of the total airborne fungi, thus these four genera are the predominant genera in the subway station.