4.5 Article

Electrocardiographic and Echocardiographic Changes in Perinatal Asphyxia

期刊

INDIAN JOURNAL OF PEDIATRICS
卷 76, 期 3, 页码 261-264

出版社

SPRINGER INDIA
DOI: 10.1007/s12098-008-0221-4

关键词

Perinatal asphyxia; Myocardial damage; Electrocardiography; Echocardiography; Outcome

向作者/读者索取更多资源

Objective. To study the usefulness of electrocardiography (ECG) and echocardiography (ECHO) in evaluating myocardial damage in perinatal asphyxia. Methods. Thirty term babies with perinatal asphyxia without any congenital malformations were selected as cases. They were compared with thirty healthy term babies without asphyxia. Myocardial dysfunction was evaluated using clinical examination, electrocardiography and echocardiography. Results. Among the 30 cases, 22 had evidence of myocardial involvement while one baby in the control group had ECG evidence of cardiac involvement. Grade I ECG changes were present in 6 (20%) cases, Grade II in 12 (40%) and Grade III in 4(13.3%). ECG was normal without any evidence of ischemia in all the controls except one baby who had ST depression with T-wave inversion. All the cases and controls had normal sinus rhythm. Tricuspid regurgitation was present in 7 (23.3%), right ventricular hypokinesia in 6 (20%) and left ventricular hypokinesia in 4(13.3%) cases. The ventricular function was normal in all the controls. Conclusion. Electrocardiography (ECG) and echocardiography (ECHO) are useful in evaluating the severity of myocardial damage in perinatal asphyxia. [Indian J Pediatr 2009; 76 (3) : 261-264] E-mail: drvishnubhat@yahoo.com

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据