4.3 Article

Fabrication of a nonenzymatic glucose sensor using Pd-nanoparticles decorated ionic liquid derived fibrillated mesoporous carbon

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.msec.2015.03.045

关键词

Pd nanoparticles; Ionic liquid derived fibrillated mesoporous; carbon materials; Nonenzymatic sensor; Glucose

资金

  1. Institute for Advanced Studies in Basic Sciences (IASBS) [G2014IASBS119]

向作者/读者索取更多资源

A novel nonenzymatic sensor was developed for glucose detection by the use of ionic liquid derived fibrillated mesoporous carbon (IFMC) decorated with palladium nanoparticles (PdNPs). PdNPs were uniformly decorated on IFMC and then the prepared nano-hybrid material (Pd@IFMC) was drop cast on the surface of a glassy carbon electrode to fabricate a glucose sensor. The prepared Pd@IFMC showed excellent electrocatalytic activity towards glucose oxidation. An oxidation peak at about +0.40 V vs. Ag|AgCl|KClsat was observed for glucose on the fabricated sensor in alkaline solution. The oxidation peak current intensity was linear towards glucose in the concentration range between I and 55 mM (R-2 = 0.9958) with a detection limit of 0.2 mM. The relative standard deviation (RSD) for repetitive measurements (n = 6) of 5 mM of glucose was of 5.3%. The fabricated sensor showed a number of great features such as ease of fabrication, wide linear range, excellent reproducibility, satisfactory operational stability and outstanding resistance towards interfering species such as ascorbic acid, uric acid, dopamine, fructose and chloride. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据