4.8 Article

Flux Balancing of Isolation Transformers and Application of The Magnetic Ear for Closed-Loop Volt-Second Compensation

期刊

IEEE TRANSACTIONS ON POWER ELECTRONICS
卷 29, 期 8, 页码 4078-4090

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2013.2294551

关键词

Magnetic analysis; magnetic cores; magnetic transducers; magnetic variables measurement; measurement; transducers

向作者/读者索取更多资源

Semiconductor switches possess nonideal behavior which, in case of isolated dc-dc converters, can generate dc-voltage components which are then applied to the isolation transformer. This dc-voltage component is translated into a dc flux density component in the transformer core, increasing the risk of driving the core into saturation. In this paper, a novel noninvasive flux density measurement principle, called The Magnetic Ear, based on sharing of magnetic path between the main and an auxiliary core is proposed. The active compensation of the transformer's dc magnetization level using this transducer is experimentally verified. Additionally, a classification of the previously reported magnetic flux measurement and balancing concepts is performed.