期刊
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
卷 55, 期 1, 页码 510-515出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNS.2007.912876
关键词
awake rat; offset delay correction; RatCAP; singular value decomposition (SVD)
The RatCAP has been designed and constructed to image the awake rat brain. In order to maximize system performance, offline digital coincidence data processing algorithms including offset delay correction and prompt and delayed coincidence detection have been developed and validated. With offset delay correction using a singular value decomposition (SVD) technique, overall time resolution was improved from 32.6 to 17.6 ns. FWHM. The experimental results confirm that the ratio of prompts to randoms was improved because a narrower timing window could be used. F-18-fluoride rat bone scan data were reconstructed using our fully 3-D ML-EM algorithm With a highly accurate detector response model created from Monte Carlo simulation.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐