4.7 Article

A Wearable Device for Real-Time Motion Error Detection and Vibrotactile Instructional Cuing

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNSRE.2011.2140331

关键词

Balance control; instructional cues; intelligent tutoring systems; movement; rehabilitation; vibrotactile

资金

  1. National Science Foundation [RAPD-0846471]
  2. University of Michigan Office of Technology Transfer

向作者/读者索取更多资源

We have developed a mobile instrument for motion instruction and correction (MIMIC) that enables an expert (i.e., physical therapist) to map his/her movements to a trainee (i.e., patient) in a hands-free fashion. MIMIC comprises an expert module (EM) and a trainee module (TM). Both the EM and TM are composed of six-degree-of-freedom inertial measurement units, microcontrollers, and batteries. The TM also has an array of actuators that provide the user with vibrotactile instructional cues. The expert wears the EM, and his/her relevant body position is computed by an algorithm based on an extended Kalman filter that provides asymptotic state estimation. The captured expert body motion information is transmitted wirelessly to the trainee, and based on the computed difference between the expert and trainee motion, directional instructions are displayed via vibrotactile stimulation to the skin. The trainee is instructed to move in the direction of the vibration sensation until the vibration is eliminated. Two proof-of-concept studies involving young, healthy subjects were conducted using a simplified version of the MIMIC system (pre-specified target trajectories representing ideal expert movements and only two actuators) during anterior-posterior trunk movements. The first study was designed to investigate the effects of changing the expert-trainee error thresholds (0.5 degrees, 1.0 degrees, and 1.5 degrees) and varying the nature of the control signal (proportional, proportional plus derivative). Expert-subject cross-correlation values were maximized (0.99) and average position errors (0.33 degrees) and time delays (0.2 s) were minimized when the controller used a 0.5 error threshold and proportional plus derivative feedback control signal. The second study used the best performing activation threshold and control signal determined from the first study to investigate subject performance when the motion task complexity and speed were varied. Subject performance decreased as motion speed and complexity increased.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据